SNMP must be installed, configured, and working on your server.
In order to run the Double-Take Availability sub-agent, master agentx is needed to turn on agentx. Add the master agent line to snmpd.conf.
master agentx
So that the SNMP daemon can locate the Double-Take Availability MIB, add the path to the Double-Take Availability MIB by adding an entry to the snmp.conf file.
mibfile /usr/share/snmp/mibs/NSI-DT-MIB.txt
Start the master agent.
#snmpd -f -Le -x /var/agentx/master &
Start the Double-Take Availability SNMP sub-agent.
#DTSubAgent >& /dev/null &
Instead of starting the master agent and Double-Take Availability sub-agent separately, you can add them both to init.d to start them automatically.
You can test SNMP by trying either of the following commands.
#snmpget -v2c -c public localhost dtGeneral.dtUpTime.0
#snmpget -v2c -c public localhost NSI-MIB::dtUpTime